FD580 Ultrasonic Flaw Detector
The FD580 portable flaw detector has a high-capacity lithium-ion battery and can therefore be operated up to 8 hours without needing to be recharged. A high-resolution color LCD display makes this instrument very operator- friendly.
download the product sheet

Features:
- Automated calibration of transducer: Zero Offset and/or Velocity
- Automated gain: Peak Hold and Peak Memory
- Automated display of precise flaw location(depth d; level p; distance s; amplitude sz; dB φ )
- Automated switch three step gauge ((depth d,level p,distance)
- Ten independent setups, any criterion can be input freely, can be operated without test block
- Large memory of 300 A-scan graphs or 30,000 thickness values
- B- scan
- RS232 communication interface
- The embedded software can be updated online
- Li battery allows continued working time up to 8 hours
- Other assisted functions
- Display freeze
- Automated echo degree
- Angles and K-value
- Lock and unlock function of system parameters
- Dormancy and screen savers
- Electronic clock calendar
- Two gates and alarm indication can be set
- High-speed capture and very low noise
- DAC,AVG,B-Scan; Solid metal housing (IP65)
- Automated make video of test process and play
- Provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness and easy to read from all angles
- Powerful PC software; reports can be exported to Excel
Technical Specification:
|
Scanning range (mm)
|
Scanning range (mm):2.5~10000Steps: 2.5, 5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 2000, 3000, 4000, 5000, 6000, 7000, 8000, 9000 and 10000.Step:0.1mm (2.5 mm~99.9mm),1mm (100mm~10000mm)
|
|
Display delay (μs)
|
D-delay (μs):-20~+3400 Stage: -20, -10, 0.0, 10, 20, 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3400.Step: 0.1 (-20μs~999.9μs), 1 (1000μs~3400μs)
|
|
Probe delay (μs)
|
P-delay: 0.0~99.99Step: 0.01
|
|
Sound velocity in material (m/s)
|
Sound velocity in material: 1000~99997 fixed sound velocities: 2260, 2730, 3080, 3230, 4700, 5900, 6300Step: 1
|
|
Working method
|
Single probe (P/R), double probes (transceiver), transmission (transmission probe)
|
|
Frequency ranges (MHz)
|
Low frequency 0.2-1, middle frequency 0.5-4, high frequency 2-20, three steps optional
|
|
Gain (dB)
|
0~110Step: 0.0, 0.2, 0.5, 1, 2, 6, 12
|
|
Linear suppression
|
0%~80% of screen height, step: 1%
|
|
Vertical linear error
|
Less than 3%
|
|
Level linear error
|
Less than 1% within scanning range
|
|
Detection sensitivity margin
|
≥60dB
|
|
Dynamic scope
|
≥60dB
|
|
Alarm
|
Traveling-wave alarm, evanescent wave alarm
|
|
Monitoring gate
|
2 gates, represents with horizontal thick line with adjustable start point, width and height.Start point(mm): horizontal pixel 0~208, with display value relating to scanning range.Step: mm quantity corresponding to one pixel (relating to scanning range)Width(mm): horizontal pixel 4~212, with display value relating to scanning range.Step: mm quantity corresponding to one pixel (relating to scanning range)Height: vertical scale 2%~90%Step: 1%
|
|
Display
|
EL highlight dot matrix4 background color available
|
|
A-Scan display
|
Full screen or partA-Scan display of freezing and de-freezing A-Scan filling
|
|
Wave display
|
All wave
|
|
Detecting channel
|
10
|
|
Data storage
|
300 A-Scan images (30 for each channel)30000 thickness values (300 groups)
|
|
Communication port with PC
|
RS232
|
|
Unit
|
mm/inch
|
|
Power adaptor
|
Input 100 Hz -240 Hz~50 Hz /60HzOutput 9V~12VDC/3A~4A
|
|
Battery
|
Li battery 4x3.6V 4000mAh
|
|
Ambient temperature (°C)
|
0~40
|
|
Ambient humidity (RH)
|
20%~90%
|
|
Interface
|
BNC
|
|
Outline (mm)
|
240x173x50
|
|
Weight (kg)
|
2.2
|
|